CHAPTER 16 LOW-VOLTAGE DETECTOR
16.1 Functions of Low-Voltage Detector
The low-voltage detector (LVI) has following functions.
•
Compares supply voltage (V
DD
) and detection voltage (V
LVI
), and generates an internal interrupt signal or
internal reset signal when V
DD
< V
LVI
.
•
Detection levels (ten levels) of supply voltage can be changed by software.
•
Interrupt or reset function can be selected by software.
•
Operable in STOP mode.
When the low-voltage detector is used to reset, bit 0 (LVIRF) of the reset control flag register (RESF) is set to 1 if
reset occurs. For details of RESF, refer to
CHAPTER 14 RESET FUNCTION
.
16.2 Configuration of Low-Voltage Detector
The block diagram of the low-voltage detector is shown in Figure 16-1.
Figure 16-1. Block Diagram of Low-Voltage Detector
LVION
Reference
voltage source
V
DD
N-ch
Low-voltage detection
level select register (LVIS)
Low-voltage detect
register (LVIM)
LVIS2
LVIMD
LVIF
INTLVI
Internal reset signal
4
V
DD
LVIS1 LVIS0
LVIS3
Low-voltage detection level selector
Selector
Internal bus
+
−