CHAPTER 10 A/D CONVERTER
User’s Manual U16898EJ3V0UD
157
Table 10-1. Sampling Time and A/D Conversion Time
f
XP
= 8 MHz
f
XP
= 10 MHz
Reference
Voltage
Range
Note 1
Sampling
Time
Note 2
Conversion
Time
Note 3
Sampling
Time
Note 2
Conversion
Time
Note 3
Sampling
Time
Note 2
Conversion
Time
Note 3
FR2 FR1 FR0
AV
REF
≥
4.5 V
12/f
XP
36/f
XP
1.5
µ
s 4.5
µ
s 1.2
µ
s 3.6
µ
s 0
0
0
AV
REF
≥
4.0 V
24/f
XP
72/f
XP
3.0
µ
s 9.0
µ
s 2.4
µ
s 7.2
µ
s 1
0
0
96/f
XP
144/f
XP
12.0
µ
s 18.0
µ
s 9.6
µ
s 14.4
µ
s 1
1
0
48/f
XP
96/f
XP
6.0
µ
s 12.0
µ
s 4.8
µ
s 9.6
µ
s 1
0
1
48/f
XP
72/f
XP
6.0
µ
s 9.0
µ
s 4.8
µ
s 7.2
µ
s 0
1
0
AV
REF
≥
2.85 V
24/f
XP
48/f
XP
3.0
µ
s 6.0
µ
s Setting
prohibited
(2.4
µ
s)
Setting
prohibited
(4.8
µ
s)
0 0 1
176/f
XP
224/f
XP
22.0
µ
s 28.0
µ
s 17.6
µ
s
22.4
µ
s 1
1
1
AV
REF
≥
2.7 V
88/f
XP
112/f
XP
11.0
µ
s 14.0
µ
s Setting
prohibited
(8.8
µ
s)
Setting
prohibited
(11.2
µ
s)
0 1 1
Notes 1.
Be sure to set the FR2, FR1, and FR0, in accordance with the reference voltage so that
Notes 2
and
3
below are satisfied.
Example When AV
REF
≥
2.7 V, f
XP
= 8 MHz
•
The sampling time is 11.0
µ
s or more and the A/D conversion time is 14.0
µ
s or more and 100
µ
s or
less.
•
Set FR2, FR1, and FR0 = 0, 1, 1 or 1, 1, 1.
2.
Set the sampling time as follows.
•
AV
REF
≥
4.5 V: 1.0
µ
s or more
•
AV
REF
≥
4.0 V: 2.4
µ
s or more
•
AV
REF
≥
2.85 V: 3.0
µ
s or more
•
AV
REF
≥
2.7 V: 11.0
µ
s or more
3.
Set the A/D conversion time as follows.
•
AV
REF
≥
4.5 V: 3.0
µ
s or more and less than 100
µ
s
•
AV
REF
≥
4.0 V: 4.8
µ
s or more and less than 100
µ
s
•
AV
REF
≥
2.85 V: 6.0
µ
s or more and less than 100
µ
s
•
AV
REF
≥
2.7 V: 14.0
µ
s or more and less than 100
µ
s
Caution The above sampling time and conversion time do not include the clock frequency error. Select the
sampling time and conversion time such that Notes 2 and 3 above are satisfied, while taking the
clock frequency error into consideration (an error margin maximum of
±
5% when using the high-
speed internal oscillator).
Remarks 1.
f
XP
: Oscillation frequency of clock to peripheral hardware
2.
The conversion time refers to the total of the sampling time and the time from successively comparing
with the sampling value until the conversion result is output.