CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
User’s Manual U16898EJ3V0UD
85
Table 6-2. CR000 Capture Trigger and Valid Edges of TI000 and TI010 Pins
(1) TI000 pin valid edge selected as capture trigger (CRC001 = 1, CRC000 = 1)
CR000 Capture Trigger
TI000 Pin Valid Edge
ES010
ES000
Falling edge
Rising edge
0
1
Rising edge
Falling edge
0
0
No capture operation
Both rising and falling edges
1
1
(2) TI010 pin valid edge selected as capture trigger (CRC001 = 0, CRC000 = 1)
CR000 Capture Trigger
TI010 Pin Valid Edge
ES110
ES100
Falling edge
Falling edge
0
0
Rising edge
Rising edge
0
1
Both rising and falling edges
Both rising and falling edges
1
1
Remarks 1.
Setting ES010, ES000 = 1, 0 and ES110, ES100 = 1, 0 is prohibited.
2.
ES010, ES000:
Bits 5 and 4 of prescaler mode register 00 (PRM00)
ES110, ES100:
Bits 7 and 6 of prescaler mode register 00 (PRM00)
CRC001, CRC000: Bits 1 and 0 of capture/compare control register 00 (CRC00)
Cautions 1. Set CR000 to other than 0000H in the clear & start mode entered on match between TM00
and CR000. This means a 1-pulse count operation cannot be performed when this
register is used as an external event counter. However, in the free-running mode and in
the clear & start mode using the valid edge of TI000 pin, if CR000 is set to 0000H, an
interrupt request (INTTM000) is generated when CR000 changes from 0000H to 0001H
following overflow (FFFFH).
2. If the new value of CR000 is less than the value of 16-bit timer counter 0 (TM00), TM00
continues counting, overflows, and then starts counting from 0 again. If the new value of
CR000 is less than the old value, therefore, the timer must be reset to be restarted after
the value of CR000 is changed.
3. The value of CR000 after 16-bit timer/event counter 00 has stopped is not guaranteed.
4. The capture operation may not be performed for CR000 set in compare mode even if a
capture trigger is input.
5. When P31 is used as the input pin for the valid edge of TI010, it cannot be used as a timer
output (TO00). Moreover, when P31 is used as TO00, it cannot be used as the input pin
for the valid edge of TI010.
6. If the register read period and the input of the capture trigger conflict when CR000 is
used as a capture register, the capture trigger input takes precedence and the read data
is undefined. Also, if the count stop of the timer and the input of the capture trigger
conflict, the capture trigger is undefined.
7. Changing the CR000 setting may cause a malfunction. To change the setting, refer to 6.5
Cautions Related to 16-Bit Timer/Event Counter 00 (17) Changing compare register
during timer operation.