CHAPTER 16 LOW-VOLTAGE DETECTOR
User’s Manual U16898EJ3V0UD
251
(2) Low-voltage detection level select register (LVIS)
This register selects the low-voltage detection level.
This register can be set by an 8-bit memory manipulation instruction.
Reset input clears this register to 00H
Note
.
Figure 16-3. Format of Low-Voltage Detection Level Select Register (LVIS)
Address: FF51H, After reset: 00H
Note
R/W
Symbol
7 6 5 4 3 2 1 0
LVIS 0 0 0 0
LVIS3
LVIS2
LVIS1
LVIS0
LVIS3 LVIS2 LVIS1 LVIS0
Detection
level
0 0 0 0
V
LVI0
(4.3 V ±0.2 V)
0 0 0 1
V
LVI1
(4.1 V ±0.2 V)
0 0 1 0
V
LVI2
(3.9 V ±0.2 V)
0 0 1 1
V
LVI3
(3.7 V ±0.2 V)
0 1 0 0
V
LVI4
(3.5 V ±0.2 V)
0 1 0 1
V
LVI5
(3.3 V ±0.15 V)
0 1 1 0
V
LVI6
(3.1 V ±0.15 V)
0 1 1 1
V
LVI7
(2.85 V ±0.15 V)
1 0 0 0
V
LVI8
(2.6 V ±0.1 V)
1 0 0 1
V
LVI9
(2.35 V ±0.1 V)
Other than above
Setting prohibited
Note
For a reset by LVI, the value of LVIM is not initialized.
Caution
Bits 4 to 7 must be set to 0.