CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
User’s Manual U16898EJ3V0UD
100
Figure 6-19. Configuration Diagram for Pulse Width Measurement by Free-Running Counter
f
XP
f
XP
/2
2
f
XP
/2
6
TI000/INTP0/P30
16-bit timer/counter 00
(TM00)
16-bit timer capture/compare
register 010 (CR010)
Internal bus
INTTM010
Selector
Figure 6-20. Timing of Pulse Width Measurement Operation by Free-Running Counter
and One Capture Register (with Both Edges Specified)
t
0000H
0000H
FFFFH
0001H
D0
D0
(D1
−
D0)
×
t
(D3
−
D2)
×
t
(D2
−
D1)
×
t
D1
D2
D3
D2
D3
D0 + 1
D1
D1 + 1
Note
Count clock
TM00 count value
TI000 pin input
CR010 capture value
INTTM010
Note
The carry flag is set to 1. Ignore this setting.
(2) Measurement of two pulse widths with free-running counter
When 16-bit timer counter 00 (TM00) is operated in free-running mode, it is possible to simultaneously
measure the pulse widths of the two signals input to the TI000 pin and the TI010 pin.
Specify both the rising and falling edges as the valid edges of the TI000 and TI010 pins, by using bits 4 and 5
(ES000 and ES010) and bits 6 and 7 (ES100 and ES110) of PRM00.
When the valid edge specified by bits 4 and 5 (ES000 and ES010) of PRM00 is input to the TI000 pin, the
value of TM00 is taken into 16-bit timer capture/compare register 000 (CR010) and an interrupt request signal
(INTTM010) is set.
Also, when the valid edge specified by bits 6 and 7 (ES100 and ES110) of PRM00 is input to the TI010 pin, the
value of TM00 is taken into 16-bit timer capture/compare register 000 (CR000) and an interrupt request signal
(INTTM000) is set.
Sampling is performed using the count clock cycle selected by prescaler mode register 00 (PRM00), and a
capture operation is only performed when a valid level of the TI000 or TI010 pin is detected twice, thus
eliminating noise with a short pulse width.