CHAPTER 21 ELECTRICAL SPECIFICATIONS (TARGET VALUES) ((T2) product)
User’s Manual U16898EJ3V0UD
343
(T2) product T
A
=
−
40 to
+
125
°
C
Notes 2.
This varies depending on the allowable total loss (see the figure below).
-40
0
+40
+80
+85
Temperature [˚C]
Total loss P
T
[mW]
+120
50
100
150
120
+125
110
Use the following formula to perform design such that the sum of the power consumption of the device is
less than or equal to the total loss P
T
(use at 80% or less of the rated value is recommended).
Total power consumption = V
DD
×
{I
DD
−
∑
I
OH
} +
∑
{(V
DD
−
V
OH
)
×
I
OH
} +
∑
(V
OH
×
I
OL
)
Caution When using the internal pull-up resistor, calculate and add the separate power
consumption.