RMX-4000 Series Programming Manual
63
RISE/FALL MIN
Sets to the slowest
rising/falling slew rate
RISE/FALL MAX
Sets to the fastest
rising/falling slew rate
Example
:CURR:STAT:HIGH:RISE 1.1
Sets the rising slew rate
to 1.1 A/µs.
Query Syntax
:CURRent:STATic:HIGH:RISE/FALL? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Slew rate
1 unit=1 A/µs
Returns the slew rate
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:CURR:STAT:HIGH:RISE?
MAX
0.8000
For high range CC mode,
the maximum value for
the rising slew rate is
0.8000 A/µs for the
specific channel.
56B
:CURRent:DYNamic:L1/L2
Channel-Specific
Command
Description
Sets the current levels (Level 1 and 2) for CC
dynamic mode. The command is range dependent.
If the current range is Low, the settings apply to
only low range.
Syntax
:CURRent:DYNamic:L1/L2 <NRf+>[A]
Parameter
NRf+[A]
Current
L1 1
Sets L1 to 1 A
L2 2
Sets L2 to 2 A
L2 2A
Sets L2 to 2 A
L1/L2 MIN
Sets L1 or L2 to the
minimum level for the
specific channel
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...