RMX-4000 Series Programming Manual
161
Query Example
:SEQ:END?
5
There are 5 points in the
sequence.
186B
:SEQuence:END:LOAD
Channel-Specific
Command
Description
Sets or queries the value of On End Load.
Syntax
:SEQuence:END:LOAD <NRf+>|MIN|MAX
Parameter
<NRf+>
Current value (CC),
resistance value (CR)
0
On End Load = Off
MIN/MAX
Maximum or minimum
value
Example
:SEQuence:END:LOAD
1.000
Sets the value of On End
Load to 1.000
Query Syntax
:SEQuence:END:LOAD?
Return Parameter OFF
On End Load is Off
<NRf>
On End Load value
Query Example
:SEQuence:END:LOAD?
1,000
On End Load value is
1.000.
187B
:SEQuence:POINt:RESistance
Channel-Specific
Command
Description
Sets the resistance value for the current point. CR
mode only.
Syntax
:SEQuence:POINt:RESistance <NRf>[OHM]|MIN|MAX
Parameter
<NRf>[OHM], MIN, MAX Resistance value
100
100
Ω
100 OHM
100
Ω
MAX/MIN
Maximum or minimum
value
Example
:SEQ:POIN:RES 100
Sets the resistance to 100.
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...