Syntax
:LOAD:SHORt[:STATe] {ON|1|OFF|0}
Parameter
ON/1
Shorting is On
OFF/0
Shorting is Off
Example
:LOAD:SHOR ON
Short circuits the load
module channel.
Query Syntax
:LOAD:SHORt[:STATe]?
Return Parameter <NR1>
Short load module
1
Shorting is activated
0
Shorting is deactivated
Query Example
:LOAD:SHOR?
0
Shorting is deactivated
on the specific channel.
74B
:LOAD:SHORt:KEY
Channel-Specific
Command
Description
You can set the SHORT key to toggle or hold
mode.
Syntax
:LOAD:SHORt:KEY {TOGGLE|1|HOLD|0}
Parameter
TOGGLE/1
Sets the SHORT key to
toggle mode
HOLD/0
Sets the SHORT key to
hold mode
Example
:LOAD:SHOR:KEY 1
Set the SHORT key to
toggle.
Query Syntax
:LOAD:SHORt:KEY?
Return Parameter <NR1>
Mode
1
Toggle mode is active
0
Hold mode is active
Query Example
:LOAD:SHOR:KEY?
0
Hold mode is active for
the specific channel.
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...