RMX-4000 Series Programming Manual
163
189B
:SEQuence:POINt:RISE/FALL
Channel-Specific
Command
Description
Sets the rising and falling slew rates for the current
point.
Syntax
:SEQuence:POINt:RISE/FALL<NRf>[A/us]|MIN|MAX
Parameter
<NRf>[A/us], MIN, MAX
Slew rate
1.2
1.2 A/us
1.2 A/us
1.2 A/us
MAX/MIN
Maximum or minimum
value
Example
:SEQ:POIN:RISE .3 A
Sets the rising slew rate
to 0.3 A/us.
:SEQ:POIN:FALL .4 A
Sets the falling slew rate
to 0.4 A/us.
Query Syntax
:SEQuence:POINt::RISE/FALL? [MAX|MIN]
Return Parameter <NR1>
Slew rate
1 unit = 1 A/us
Returns the slew rate
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:SEQ:POIN:RISE?
0.30000
Returns the rising slew
rate (0.3 A/us).
:SEQ:POIN:FALL?
0.40000
Returns the falling slew
rate (0.4 A/us).
190B
:SEQuence:POINt:TIME
Channel-Specific
Command
Description
Sets the duration time of the current point in
seconds.
Syntax
:SEQuence:POINt:TIME <NRf>[S]|MIN|MAX
Parameter
<NRf>
Duration Time
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...