RMX-4000 Series Programming Manual
94
Query Example
:OCP:CHAN:TRIG?
5.0
Returns the trigger level.
97B
:OCP:CHANnel:ACTive
Channel-Specific
Command
Description
Queries or sets which bit(s) are the active channel
for the OCP Test Automation function. More than
one channel can be activated based on the bit
weight of the parameter.
Syntax
:OCP:CHANnel:ACTive {<NR1>0~255}
Parameter
<NR1>
(BIT WEIGHT)
Channel
number
<NR1>
(BIT WEIGHT)
Channel
number
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8
Example
:OCP:CHAN:ACT 3
Activates channel 1 and
2.
Query Syntax
:OCP:CHANnel:ACTive?
Return Parameter <NR1>
(BIT WEIGHT)
Channel
number
<NR1>
(BIT WEIGHT)
Channel
number
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8
Query Example
:OCP:CHAN:ACT?
4
Returns channel 4 as
the active channel.
98B
:OCP:STATus?
Query
Description
Queries the OCP Test Automation function status.
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...