RMX-4000 Series Programming Manual
166
Description
Determines from which point to start repeating
(looping) the sequence from when using the
SEQuence:REPeat command.
Syntax
:SEQuence:LOOP:STARt <NR1>
Parameter
<NR1>
Start loop from
1~last point
1st~last point
Example
:SEQ:LOOP:STAR 2
Loop from point 2.
Query Syntax
:SEQuence:LOOP:STARt?
Return Parameter <NR1>
Point
1~last point
Returns the point that the
loop will start from
Query Example
:SEQ:LOOP:STAR?
2
The loop starts at point
2.
194B
:SEQuence:CHANnel:TIME
Channel-Specific
Command
Description
Sets which channel duration time the specific
channel will use.
Syntax
:SEQuence:CHANnel:TIME <NR1>
Parameter
<NR1>1~max channels
Duration Time Settings
1
Use channel 1
2 etc.
Use channel 2, etc.
Example
:SEQ:CHAN:TIME 3
Set the specific channel
to use the channel
duration time of channel
3.
Query Syntax
:SEQuence:CHANnel:TIME?
Return Parameter <NR1>
Point
1~max channels
Returns the channel
duration time that the
specific channel is using
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...