RMX-4000 Series Programming Manual
40
22B
:CONFigure:VOLTage:LATch
Channel-Specific
Command
Description
Turn Von Latch on or off for the specific channel.
Syntax
:CONFigure:VOLTage:LATch {OFF|0|ON|1}
Parameter
{OFF|0|ON|1}
Von Latch
OFF/0
Off
ON/1
On
Example
:CONF:VOLT:LAT 1
Sets Von latch to ON.
Query Syntax
:CONFigure:VOLTage:LATch?
Return Parameter <NR1>
Von latch status
0
Latched Off
1
Latched On
Query Example
:CONF:VOLT:LAT?
1
Von latch is set to ON.
23B
:CONFigure:AUTO:LOAD
All Channels
Description
Configures the electronic load for Auto Load On or
Off at start up.
Syntax
:CONFigure:AUTO:LOAD {OFF|0|ON|1}
Parameter
{OFF|0|ON|1}
Auto Load
OFF/0
Off
ON/1
On
Example
:CONF:AUTO:LOAD ON
Configures Auto Load to
On.
Query Syntax
:CONFigure:AUTO:LOAD?
Return Parameter <NR1>
Auto Load Status
0
Off
1
On
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...