RMX-4000 Series Programming Manual
59
Query Example
:CURR:STAT:L2? MAX
10.2
Returns the maximum
current allowed for the
channel. (RMX-4003)
Query Example
:CURR:STAT:L2? 2
Returns the current
setting (2 A) for B Value.
51B
:CURRent:STATic:RISE/FALL
Channel-Specific
Command
Description
Sets the slew rate for constant current static mode.
The command is range dependent. If the current
range is Low, the command applies to only the low
range settings.
Syntax
:CURRent:STATic:RISE/FALL <NRf+>[A/µs]
Parameter
<NRf+>[A/µs]
Slew rate
RISE/FALL 0.078 A/µs
Sets the rising/falling slew
rate to 0.078 A/µs
RISE/FALL 1
Sets the rising/falling slew
rate to 1 A/µs
RISE/FALL MIN
Sets to the slowest
rising/falling slew rate
RISE/FALL MAX
Sets to the fastest
rising/falling slew rate
Example
:CURR:STAT:RISE .01
Sets the rising slew rate
to 0.01 A/µs.
Query Syntax
: CURRent:STATic:RISE/FALL? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Slew rate
1 unit=1 A/µs
Returns the slew rate
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:CURR:STAT:RISE? MIN
0.078
The minimum value for
the rising slew rate is
0.078 A/µs for the
specific channel.
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...