RMX-4000 Series Programming Manual
43
1
Updated
Query Example
:CONF:LOAD?
0
Sets the load module
selector configuration
type as OLD.
28B
:CONFigure:PROTection:CURRent:STATe
Channel-Specific
Command
Description
Sets the current protection for the specific channel
on or off. The current protection can also be
cleared.
Syntax
:CONFigure:PROTection:CURRent:STATe
{OFF|0|ON|1|CLEAR|2}
Parameter
CLEAR/2
Cleared
OFF/0
Off
ON/1
On
Example
:CONF:PROT:CURR:STAT 1
Turns on current protection.
Query Syntax
: CONFigure:PROTection:CURRent:STATe?
Return Parameter <NR1>
Current Protection
0
Off
1
On
2
Clear
Query Example
:CONF:PROT:CURR:STAT?
1
Current protection is
turned on.
29B
:CONFigure:PROTection:CURRent:LEVel
Channel-Specific
Command
Description
Sets the current protection level for the
current/specific channel. You can set the level to
any applicable level or to the channel
maximum/minimum.
Syntax
:CONFigure:PROTection:CURRent:LEVel
<NRf>[A]|MIN|MAX
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...