RMX-4000 Series Programming Manual
68
61B
:CURRent:DYNamic:LOW:T1/T2
Channel-Specific
Command
Description
Sets the low range timers T1 or T2 for CC dynamic
mode for the specific channel.
Syntax
:CURRent:DYNamic:LOW:T1/T2 <NRf+>[S/ms]
Parameter
<NRf+>[S/ms]
Time
T1/T2 0.1S
Sets the T1/T2 time to
0.1 s
T1/T2 1
Sets T1/T2 to 1 s
T1/T2 MIN
Sets the T1/T2 to the
minimum value
T1/T2 MAX
Sets the T1/T2 time to the
maximum time
Example
:CURR:DYNA:LOW:T1 .1S
Sets the T1 time to
100 ms for the specific
channel.
Query Syntax
: CURRent:DYNamic:LOW:T1/T2? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Time
1 unit=1 s
Returns T1/T2 time
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:CURR:DYN:LOW:T1?
2.5
:CURR:DYN:LOW:T1? MIN
0.000025
Returns the T1 time of
2.5 s.
Returns the minimum T1
time allowable for the
specific channel.
62B
:CURRent:DYNamic:HIGH:L1/L2
Channel-Specific
Command
Description
Sets the high range current levels (Level 1 and 2)
for CC dynamic mode.
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...