RMX-4000 Series Programming Manual
58
1
B
Query Example
:CURR:STAT:REC?
0
A Value is active.
50B
:CURRent:STATic:L1/L2
Channel-Specific
Command
Description
Sets the A/B Value for constant current static
mode, where L1 is A Value and L2 is B Value. The
command is range dependent. If the current range
is Low, the command applies to only the low-
range settings.
Syntax
:CURRent:STATic:L1|L2 <NRf+>[A]
Parameter
<NRf+>[A]
L1 1
Sets A Value to 1 A
L2 2
Sets B Value to 2 A
L1 1A
Sets A Value to 1 A (single
channel only)
L1 MIN
Sets A Value to the
minimum level for the
specific channel
L1 MAX
Sets A Value to the
maximum level for the
specific channel
Example
:CURR:STAT:L1 1
Sets A Value to 1 A for
the current range.
Query Syntax
:CURRent:STATic:L1?/L2? [MAX|MIN]
Return Parameter <NR2> [MAX|MIN]
Current
1 unit = 1 A
Returns the A Value (L1) or
B Value (L2) current
MAX/MIN
Returns the allowable
maximum and minimum
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...