RMX-4000 Series Programming Manual
70
RISE/FALL 0.8 A/µs
Sets the rising/falling slew
rate to 0.8 A/µs
RISE/FALL 1
Sets the rising/falling slew
rate to 1 A/µs
RISE/FALL MIN
Sets to the slowest
rising/falling slew rate
RISE/FALL MAX
Sets to the fastest
rising/falling slew rate
Example
:CURR:DYNA:HIGH:RISE
1.1
Sets the rising slew rate
to 1.1 A/µs.
Query Syntax
: CURRent:DYNamic:HIGH:RISE/FALL? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Slew rate
1 unit = 1 A/µs
Returns the slew rate
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:CURR:DYN:HIGH:FALL?
MAX
0.8
For high range dynamic
CC mode, the maximum
value for the falling slew
rate is 0.8 A/µs for the
specific channel.
64B
:CURRent:DYNamic:HIGH:T1/T2
Channel-Specific
Command
Description
Sets the timers T1 or T2 for CC dynamic mode for
the specific channel in high range.
Syntax
:CURRent:DYNamic:HIGH:T1/T2 <NRf+>[S|ms]
Parameter
<NRf+>[S]
Time
T1/T2 0.1S
Sets the T1/T2 time to
0.1 s
T1/T2 1
Sets T1/T2 to 1 s
T1/T2 MIN
Sets the T1/T2 to the
minimum value
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...