RMX-4000 Series Programming Manual
165
Query Example
:SEQ:REP?
10
Repeats the sequence 10
times.
192B
:SEQuence:VOLTage:RANGe
Channel-Specific
Command
Description
Sets the sequence CC voltage range.
Syntax
:SEQuence:VOLTage:RANGe <NRf>[V]|L|H
Parameter
<NRf>[ V] , L, H
Range
16
Low range*
80V
High range*
L
Low range
H
High range
*Load module dependent, RMX-4003 shown.
Example
:SEQ:VOLT:RANG L
Sets the range to Low for
the channel.
Query Syntax
:SEQuence:VOLTage:RANGe?
Return Parameter <NR2>
Range
16
Low RMX-4003, 4004,
4005
125
Low RMX-4006
80
High RMX-4003, 4004,
4005
500
High RMX-4006
Query Example
:SEQ:VOLT:RANG?
500
Returns the voltage
range. In this case, high
for the RMX-4006.
193B
:SEQuence:LOOP:STARt
Channel-Specific
Command
Содержание RMX-400 Series
Страница 1: ...Programmable DC Electronic Load RMX 400x Series PROGRAMMING MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Страница 23: ...RMX 4000 Series Programming Manual 23 Memory Subsystem 153 SEQuence Subsystem 159 GLOBal Subsystem 170...
Страница 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Страница 37: ...RMX 4000 Series Programming Manual 37 Query Example MEM this is a memo Returns the memo message...
Страница 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Страница 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Страница 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...
Страница 134: ...RMX 4000 Series Programming Manual 134 Questionable Status NTR All bits set to 0 Syntax STATus PREset Example STAT PRE...