Falcon II Outdoor series printers – Maintenance Manual
320
AP-74065, Rev. 1.0, 21/11/03
(2) Check if the
tension of the steel
belt is adjusted
correctly.
• Adjust the steel
belt tension.
→
Steel belt tension
adjustment
(3) Check the T
fence for
contamination.
• Clean the T fence
• If the contaminants
cannot be cleaned
up, replace the T
fence.
→
Replacing the T
fence.
A: Paper discharging direction
(4) The internal
process operation of
the Mainboard
assembly may be
malfunctioning.
• Check the
operation again
after initializing
parameters and re-
inputting and re-
adjusting them.
→
Parameter
initialization menu.
(1) Make sure that
the PF reduction
belt tension is
adjusted correctly.
• Adjust the tension
of the PF reduction
belt.
→
PF deceleration
belt tension
adjustment.
(2) Check the
rotation of the
pressure roller with
the pressure arm at
the raised position.
• If the surrounding
area of the pressure
arm is contaminated
by paper, wipe it
with a soft
dampened cloth.
→
User’s Guide
19
Straight lines in the head travel
direction are not accurate
(straightness)
A: Paper discharging direction
(3) Check if rattles
are heard when the
carriage is moved
from side to side.
•Clean the dust from
the carriage
bearings and roller
guide. When the
roller guide is
cleaned, apply a
light coat of grease
on the roller guide
using a cloth soaked
in grease spray.
• Replace the CR
cursor assembly
→
Replacing the CR
cursor assembly.
(1) Check if the use
conditions are within
the normal
operation
conditions.
• Be sure to use the
product under the
operation
conditions.
-
(2) Check if distance
is compensated for
the paper in use.
• Compensate the
distance.
→
Band feed
correction menu
(3) Check the PF
drive pulley for
looseness.
• Replace the PF
motor assembly.
→
Replacing the PF
motor assembly.
20
A limited line in the paper feed
direction is not accurate ( in the
sub scanning direction)
(4) Make sure that
the PF reduction
belt tension is
adjusted correctly.
• Adjust the tension
of the PF reduction
belt.
→
PF deceleration
belt tension
adjustment