![MUTOH Falcon II Outdoor Скачать руководство пользователя страница 205](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155205.webp)
Falcon II Outdoor series printers – Maintenance Manual
205
AP-74065, Rev. 1.0, 21/11/03
5.9.7. Lever Motor Endurance Menu
This menu performs endurance running for the lever motor.
You can drive the lever motor according to your desired settings. The available settings are shown below.
Setup item
Description
Parameters
Remarks
Number of endurance
running cycles
Set the number of
endurance running
cycles
-1 to 10000
Notes :
¾
If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
¾
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
* LifeCount *
Count
-1
→
10000 + Number of endurance running cycles
50
-
↓
ENTER
*
LeverMotor
*
Count
5 Perform endurance running
↓
ENTER or CANCEL
*
LeverMotor
*
End
50