![MUTOH Falcon II Outdoor Скачать руководство пользователя страница 264](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155264.webp)
Falcon II Outdoor series printers – Maintenance Manual
264
AP-74065, Rev. 1.0, 21/11/03
Step 5 :
Connect up the tubing for pump 4 as shown in the figure below.
1 = Tube connecting to waste fluid tube
2 = Tube connecting to cap 5
3 = Tube connecting to cap 8
Step 6 :
Insert in the waste fluid tubes from the pumps a piece of 15 cm tube (DF-43951).
1 = piece of tube (15 cm)
Step 7 :
Stick the locking wire saddle onto side plate F.
Step 8 :
Bundle the tubes and connectors together in the locking wire saddle.
Step 9 :
Bundle the waste fluid tubes in the large waste fluid tube.