EDS-508A/505A Series User’s Manual
Featured Functions
3-33
Redundancy Protocol
Setting
Description
Factory Default
Turbo Ring
Select this item to change to the Turbo
Ring configuration page.
Turbo Ring V2
Select this item to change to the Turbo
Ring V2 configuration page.
Turbo Chain
Select this item to change to the Turbo
Chain configuration page
RSTP (IEEE
802.1W/1D)
Select this item to change to the RSTP
configuration page.
None
Ring redundancy is not active
None
Set as Master
Setting
Description
Factory Default
Enabled
Select this EDS as Master
Disabled
Do not select this EDS as Master
Not checked
Redundant Ports
Setting
Description
Factory Default
1st Port
Select any port of the EDS to be one
of the redundant ports.
EDS-505A: port 4
EDS-508A: port 7
2nd Port
Select any port of the EDS to be one
of the redundant ports.
EDS-505A: port 5
EDS-508A: port 8
Enable Ring Coupling
Setting
Description
Factory Default
Enable
Select this EDS as Coupler
Disable
Do not select this EDS as Coupler
Not checked
Coupling Port
Setting
Description
Factory Default
Coupling Port
Select any port of the EDS to be the
coupling port
EDS-505A: port 2
EDS-508A: port 5
Coupling Control Port
Setting
Description
Factory Default
Coupling Control Port
Select any port of the EDS to be the
coupling control port
EDS-505A: port 3
EDS-508A: port 6
Configuring “Turbo Ring V2”