EDS-508A/505A Series User’s Manual
Modbus/TCP Map
B-2
0x0055
3 word
Ethernet MAC Address
Ex: MAC = 00-01-02-03-04-05
Word 0 Hi byte = 0x00
Word 0 Lo byte = 0x01
Word 1 Hi byte = 0x02
Word 1 Lo byte = 0x03
Word 2 Hi byte = 0x04
Word 2 Lo byte = 0x05
0x0058 1
word
Power
1
0x0000:Off
0x0001:On
0x0059 1
word
Power
2
0x0000:Off
0x0001:On
0x005A
1 word
Fault LED Status
0x0000:No
0x0001:Yes
0x0080 1
word
DI1
0x0000:Off
0x0001:On
0x0081 1
word
DI2
0x0000:Off
0x0001:On
0x0082 1
word
DO1
0x0000:Off
0x0001:On
0x0083 1
word
DO2
0x0000:Off
0x0001:On
Port Information
0x1000~0x1011
1 word
Port 1~5 Status
0x0000:Link down
0x0001:Link up
0x0002:Disable
0xFFFF:No port
0x1100~0x1111
1 word
Port 1~5 Speed
0x0000:10M-Half
0x0001:10M-Full
0x0002:100M-Half
0x0003:100M-Full
0x0004:1G-Half
0x0005:1G- Full
0xFFFF:No port
0x1200~0x1211
1 word
Port 1~5 Flow Ctrl
0x0000:Off
0x0001:On
0xFFFF:No port
0x1300~0x1311
1 word
Port 1~5 MDI/MDIX
0x0000:MDI
0x0001:MDIX
0xFFFF:No port