EDS-508A/505A Series User’s Manual
Featured Functions
3-25
1
st
Trap Server IP/Name
Setting
Description
Factory Default
IP or Name
Enter the IP address or name of the 1
st
Trap Server used by your network.
None
1
st
Trap Community
Setting
Description
Factory Default
Character String
Use a community string match for
authentication (maximum of 30
characters).
Public
2nd Trap Server IP/Name
Setting
Description
Factory Default
IP or Name
Enter the IP address or name of the 2
nd
Trap Server used by your network.
None
2nd Trap Community
Setting
Description
Factory Default
Character String
Use a community string match for
authentication (maximum of 30
characters).
Public
Inform mode select
Setting
Description
Factory Default
Retries
Enter Inform Retry number
1
Time out
Enter Inform Timeout window
1
Private MIB information
Switch Object ID
Setting
Description
Factory Default
8691.7.9 for EDS-508A;
8691.7.8 for EDS-505A
EDS-508A/505A’s enterprise value
Fixed
NOTE: The Switch Object ID cannot be changed.
Using Communication Redundancy
Setting up Communication Redundancy on your network helps protect critical links against failure,
protects against network loops, and keeps network downtime at a minimum.