EDS-508A/505A Series User’s Manual
Featured Functions
3-20
When configuring Port Trunking, note that:
Each EDS-505A can set a maximum of 2 Port Trunking groups (designated Trk1, Trk2). Each
EDS-508A can set a maximum of 4 Port Trunking groups (designated Trk1, Trk2, Trk3, Trk4)
When you activate Port Trunking settings, some advanced functions that you setup with the
original ports will either be set to factory default values, or disabled:
Communication Redundancy will be set to the factory default
Traffic Prioritization will be set to the factory default
Port-based VLAN or 802.1Q VLAN will be set to the factory default
Multicast Filtering will be set to the factory default
Rate Limiting will be set to the factory default
Port Access Control will be set to the factory default
Email and Relay Warning will be set to the factory default
Set Device IP will be set to the factory default
Mirror Port will be set to the factory default
You can setup these features again on your Trunking Port.
Configuring Port Trunking
The
Port Trunking Settings
page is used to assign ports to a Trunk Group.
Step 1:
Select Trk1, Trk2, Trk3, or Trk4 from the
Trunk Group
drop-down box.
Step 2:
Select Static, or LACP from the
Trunk Type
drop-down box.
Step 3:
Under
Member Ports
and
Available Ports
, select the specific ports.
Step 4:
Use
the
Up
/
Down
buttons to add/remove designated ports to/from a trunk group.