![Motortech DetCon series Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/motortech/detcon-series/detcon-series_operating-manual_1839330074.webp)
8 DenEdit Settings
74
Rev. 02/2019
8.5
Display Area of the Analog Output Signal and the Knocking Intensity
The output signal of the analog outputs and the knocking intensity are displayed using two
graphic indicating instruments.
Normalized analog output
The left display shows the value of the signal currently present at the analog outputs. The value
is displayed as a percentage of the output range (0-5 V / 4-20 mA). In addition, the displayed
value is indicated numerically on the upper left.
Knocking intensity
Various knocking intensity values can be indicated on the right display. The values are shown as
a percentage of the maximum value. The selection of the displayed value is made in the tab
Mode
. Refer to the section
Tab: Mode
on page 78.
The current minimum and maximum values are also indicated numerically above the display. The
numerical display for the maximum value (upper right) also indicates on which cylinder this
value was measured.
8.6
Error and Status Displays
The status displays indicate the status of the binary outputs and the error displays show errors
which arise during the internal diagnostics check of the control device. The different lights of the
displays indicate the following:
Содержание DetCon series
Страница 1: ...DetCon Detonation Controller Operating Manual P N 01 30 002 Rev 02 2019...
Страница 23: ...4 Product Description Rev 02 2019 23...
Страница 24: ...4 Product Description 24 Rev 02 2019...
Страница 25: ...4 Product Description Rev 02 2019 25...
Страница 26: ...4 Product Description 26 Rev 02 2019...
Страница 27: ...4 Product Description Rev 02 2019 27...
Страница 37: ...4 Product Description Rev 02 2019 37 DetCon20 Dimensions...
Страница 89: ......
Страница 90: ......