6 Wiring of the Device
60
Rev. 02/2019
6.3
Wiring of the Ignition Sensor Unit (ISU)
In order to transfer the ignition pulse of the first cylinder in the firing order to the ignition input
of the DetCon, the ignition sensor unit (ISU) is installed between the ignition output of the first
cylinder and the primary side of the ignition coil of the first cylinder. The jumper with the
designation
Load Resistance
must not have been removed.
Position Load Resistance Jumper
The jumper
Load Resistance
changes the input resistance of the ignition
input.
–
Jumper set: 220
–
Jumper removed: 1 k
It is on the upper left of the device
.
If not all cylinders are fitted with detonation sensors, the ignition sensor unit is mounted on the
cylinder on which the first detonation sensor is mounted.
Principle Circuit Diagram
Ignition
controller
Ignition output
1st cylinder
Ignition sen-
sor unit (ISU)
Primary side of
ignition coil
1st cylinder
Ignition coil
1st cylinder
Содержание DetCon series
Страница 1: ...DetCon Detonation Controller Operating Manual P N 01 30 002 Rev 02 2019...
Страница 23: ...4 Product Description Rev 02 2019 23...
Страница 24: ...4 Product Description 24 Rev 02 2019...
Страница 25: ...4 Product Description Rev 02 2019 25...
Страница 26: ...4 Product Description 26 Rev 02 2019...
Страница 27: ...4 Product Description Rev 02 2019 27...
Страница 37: ...4 Product Description Rev 02 2019 37 DetCon20 Dimensions...
Страница 89: ......
Страница 90: ......