5 Installation Instructions
52
Rev. 02/2019
–
On the cylinder head screws
Especially when it comes to engine conversions, it has proven to be worthwhile to attach the
knocking sensors on cylinder head screws or -bolts.
Drill an M6-hole with a maximum depth of 12 mm (0.47") in the cylinder head screw and fix
the
detonation sensor
with a screw of type M 6x25-10.9 and an adapter sleeve to fill the
hollow space
–
On the nuts of the cylinder head studs
Contact the engine manufacturer if you are not sure whether the cylinder head screw is suitable
for the installation.