5 Installation Instructions
50
Rev. 02/2019
Dimensions of the Required Bore
An M6 screw can also be used as an alternative to M8 screw for the mounting of the
detonation
sensor
. In this case, however, an adapter sleeve must be used in the sensor to close in the
resultant hollow space, thus ensuring optimal signal transmission.
Mounting
In order to ensure the best functioning of the DetCon detonation controller, it is mandatory to
install the sensors as follows:
–
There must be a direct connection to the engine block.
–
Installations without a direct connection to the engine block (e. g. with sealings) are
unsuitable.
–
Only the metal surface of the sensor may rest on the engine.
–
Do not use washers, spring washers, or toothed washers.
–
The knocking sensors may not come into contact with liquids (e. g. oil, coolant, water) over a
longer period of time