6 Wiring of the Device
58
Rev. 02/2019
6.2
Wiring for Ignition Controller with ASO Output
No ignition sensor unit (ISU) is required when you use the ignition controller with ASO output
from MOTORTECH (e. g. MIC6). In this case, the ignition pulse is transmitted to the DetCon via
the auxiliary synchronization output (ASO). The jumper identified with
Load Resistance
must be
removed.
Position Load Resistance Jumper
The jumper
Load Resistance
changes the input resistance of the ignition
input.
–
Jumper set: 220
–
Jumper removed: 1 k
It is on the upper left of the device
.