Chapter Four: Analog and Digital Interface
Digital Interface Input and Output Options
42
The switch positions are numbered in a clockwise direction, to correspond to the increasing address values.
PGM
250
500
125
(Kb)
Baud Rate
Figure 13: Devicenet Baud Rate Switch
DeviceNet MAC ID (Node Address) Switches
Two 10-position rotary switches, shown below, are used to set the MAC ID (node address).
The MAC ID is an integer identification value assigned to each node on the DeviceNet network.
PGM
6
4
0
2
Node Address
(00-63)
4
8
0
2
Sets least
significant digit
6
Sets most
significant digit
Figure 14: Devicenet MAC ID Switches
The valid MAC ID switch positions are 0 to 63. Use the switch on the left to set the most significant digit
(MSD), that is, the factor of ten (10, 20, 30...60). Use the switch on the right to set the least significant digit
(LSD), that is, the increments of one (1, 2, 3...9). The switch positions are numbered in a clockwise direction,
to correspond to the increasing address values.
Note
Setting the switches to a value that is greater than 63 is the same as setting the rotary switch to
the “PGM” position (the baud rate is read from the non-volatile memory).
Note
The MAC ID switch on the top of the device must be set to the network (PGM) position before
power up in order for changes to be made over the network. Any changes in the rotary switch
positions after power up are ignored.
Содержание P9B
Страница 1: ...1042936 001 Rev A January 2013 MKS Type P9B Digital Mass Flow Controller Instruction Manual...
Страница 4: ......
Страница 10: ...List of References vi This page intentionally left blank...
Страница 20: ......
Страница 22: ...12...
Страница 23: ...13 MKS Instruments Inc MKS Calibration and Service Center...
Страница 24: ...14...
Страница 26: ...16 MKS Instruments Inc MKS MKS Calibration and Service Center...
Страница 27: ...17...
Страница 28: ...18...
Страница 32: ......
Страница 56: ...Chapter Four Analog and Digital Interface Digital Interface Input and Output Options 46...
Страница 64: ......
Страница 68: ...Chapter Five Ethernet Interface Setup and Configuration Digital Interface Input and Output Options 58...
Страница 86: ...Chapter Six Embedded Web Based GUI and Diagnostics Tuning the MFC for Optional PC 76...
Страница 92: ...Chapter Seven Maintenance Pressure Zero Adjustment 82 This page intentionally left blank...
Страница 99: ...Troubleshooting Chart Chapter Eight Troubleshooting 89 This page intentionally left blank...
Страница 100: ......
Страница 105: ...Appendix A Product Specifications Electrical Specifications 95...
Страница 111: ...Model Code Description 101...
Страница 112: ...Model Code Description Appendix C Health and Safety Form 102 Appendix C Health and Safety Form...