APPX
Appendix 5 List of Link Special Register (SW)
283
A
SW01C8 to
SW01CF
Synchronous/
asynchronous
operating status
information of
each station
Stores the information about operating status of the CC-Link IE TSN Network
synchronous communication function for each station.
0: Asynchronous setting
1: Synchronous setting
Stations which are not executing an inter-module synchronous interrupt program
because the CPU operating status is currently STOP or PAUSE (the status under
which the program cannot be executed) are also treated as asynchronous setting
(0).
Each number in the table represents a station number.
is fixed to 0.
(Conditions)
• Stations that surpass the maximum station number are ignored.
SW01D0 to
SW01D7
Watchdog
counter
operating status
information for
each station
Stores the watchdog counter operating status information for each station in CC-
Link IE TSN communications. (Station number: 1 to 120)
0: Not operating
1: Operating
Stations which are not performing data links are treated as "0: Not operating"
because the information indicates that slave stations are communicating using
the watchdog counter.
Each number in the table represents a station number.
is fixed to 0.
(Conditions)
• Stations that surpass the maximum station number are ignored.
SW01E9
Inter-module
synchronization
cycle over count
Indicates the number of times cyclic data transfer processing is not completed
within the inter-module synchronization cycle. The status is cleared by powering
off and on the system or by resetting the CPU module.
0: Cycle over not occurred
1 to 65535: Cumulative number of times
When FFFFH (maximum value 65535) is counted, counting stops.
SW01EA to
SW01EB
Inter-module
synchronization
cycle setting
value
Stores the cycle setting value of the fixed interval synchronization of Inter-module
synchronization. (Unit:
s)
"0" is stored when the inter-module synchronization function is not used.
SW025A
Remote device
forced output
request result
Stores the request result of 'Remote device forced output request' (SB0016).
0: Normal
1 or greater: Not completed
If not completed, an error code is stored.
When 'Remote device forced output request' (SB0016) is turned off, the stored
error code is cleared.
No.
Name
Description
Availability
Master
station
Local station
Unicast
mode
Multicast
mode
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SW01C9
SW01CA
SW01CB
SW01CC
SW01CD
SW01CE
SW01CF
SW01C8
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SW01D1
SW01D2
SW01D3
SW01D4
SW01D5
SW01D6
SW01D7
SW01D0
Содержание MELSEC iQ-R CC-Link IE TSN
Страница 1: ...MELSEC iQ R CC Link IE TSN User s Manual Application RJ71GN11 T2 ...
Страница 2: ......
Страница 160: ...158 3 PROGRAMMING 3 3 Communication Example of Safety Communication Master station station No 0 ...
Страница 323: ...APPX Appendix 10 Added and Enhanced Functions 321 A MEMO ...
Страница 325: ...I 323 MEMO ...
Страница 329: ......