![Mitsubishi Electric MELSEC iQ-R CC-Link IE TSN Скачать руководство пользователя страница 252](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r-cc-link-ie-tsn/melsec-iq-r-cc-link-ie-tsn_user-manual_1811879252.webp)
250
APPX
Appendix 3 Buffer Memory
Details of buffer memory addresses
Link device area
The RX, RY, RWw, RWr, LB, LW, SB, and SW values are stored.
■
Remote input (RX) (Un\G57344 to Un\G58367)
The RX value is stored. The RX start number and number of points for each station number can be checked by the RX offset/
size information (Un\G1245696 to Un\G1246179). (
Page 252 RX offset/size information)
Each bit corresponds to 1 bit of RX.
■
Remote output (RY) (Un\G58368 to Un\G59391)
The RY value is stored. The RY start number and number of points for each station number can be checked by the RY offset/
size information (Un\G1246720 to Un\G1247203). (
Page 253 RY offset/size information)
Each bit corresponds to 1 bit of RY.
■
Remote register (RWw) (Un\G59392 to Un\G67583)
The RWw value is stored. The RWw start number and number of points for each station number can be checked by the RWw
offset/size information (Un\G1247744 to Un\G1248227). (
Page 254 RWw offset/size information)
■
Remote register (RWr) (Un\G67584 to Un\G75775)
The RWr value is stored. The RWr start number and number of points for each station number can be checked by the RWr
offset/size information (Un\G1248768 to Un\G1249251). (
Page 254 RWr offset/size information)
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G57344
RX
F
RX
E
RX
D
RX
C
RX
B
RX
A
RX
9
RX
8
RX
7
RX
6
RX
5
RX
4
RX
3
RX
2
RX
1
RX
0
Un\G58367
RX
3FFF
RX
3FFE
RX
3FFD
RX
3FFC
RX
3FFB
RX
3FFA
RX
3FF9
RX
3FF8
RX
3FF7
RX
3FF6
RX
3FF5
RX
3FF4
RX
3FF3
RX
3FF2
RX
3FF1
RX
3FF0
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G58368
RY
F
RY
E
RY
D
RY
C
RY
B
RY
A
RY
9
RY
8
RY
7
RY
6
RY
5
RY
4
RY
3
RY
2
RY
1
RY
0
Un\G59391
RY
3FFF
RY
3FFE
RY
3FFD
RY
3FFC
RY
3FFB
RY
3FFA
RY
3FF9
RY
3FF8
RY
3FF7
RY
3FF6
RY
3FF5
RY
3FF4
RY
3FF3
RY
3FF2
RY
3FF1
RY
3FF0
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G59392
RWw0
Un\G59393
RWw1
Un\G67583
RWw1FFF
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G67584
RWr0
Un\G67585
RWr1
Un\G75775
RWr1FFF
Содержание MELSEC iQ-R CC-Link IE TSN
Страница 1: ...MELSEC iQ R CC Link IE TSN User s Manual Application RJ71GN11 T2 ...
Страница 2: ......
Страница 160: ...158 3 PROGRAMMING 3 3 Communication Example of Safety Communication Master station station No 0 ...
Страница 323: ...APPX Appendix 10 Added and Enhanced Functions 321 A MEMO ...
Страница 325: ...I 323 MEMO ...
Страница 329: ......