Torque Frequency Output
The torque signal differential input from the torque transducer can be converted to a single end output
using the ground as the datum and then output.
Frequency Output Specifications (Model: OPT-564-T4)
When F-54 = 0
Specifications
Details
Output range
5 kHz to 15 kHz
Output voltage
0 to 5 V
Non-linearity
Within 0.01 % R.O.
Resolution
Approx. 0.5 Hz or more
Over-range
4 kHz for [-OL] indication
16 kHz for [OL] indication
Group delay time 20 ms
When F-54 = 1
Specifications
Details
Output range
120 kHz to 360 kHz
Output voltage
0 to 5 V
Non-linearity
Within 0.01 % R.O.
Resolution
Approx. 12 Hz or more
Over-range
96 kHz for [-OL] indication
384 kHz for [OL] indication
Group delay time 20 ms
Frequency Output Adjustment
No zero or span adjustment functions are available for frequency output. The frequency input is output
unmodified. Users should make any necessary adjustments on their own equipment.