Torque Analog Output Connection
The individual analog output connection methods are described here.
The standard model features only the voltage output from T-A-OUT1. If current or frequency output is
required, this should be specified at the time of purchase.
Use shielded cable for the analog output connections, and connect the shield wire to the protective
ground connector.
Voltage Output
Current Output
The voltage output connection destination varies depending on the particular model. For further
details, see the table in Section 2-5. The connection example shown above applies to the
OPT-564-T24/OPT-564-T34 models.
+
V
-
Shield
Load resistance
2 kΩ or more
Capacitance load
0.1 μF or less
Load resistance
510 Ω or less
+
Shield
-