4
Connections
Wiring Precautions
Always turn off power before connecting or disconnecting the equipment.
Do not turn on the AC power until all installation work is complete. There is no ON/OFF switch on the
unit itself.
Do not drop the equipment or subject it to strong impact.
Be sure to attach the acrylic cover provided on the power supply connector board before use.
Tighten the terminal screws on the connector boards to the following torques:
Connector board
Connector board screw
tightening torque
Power supply
connector board
1.4 N
m
Connector
0.25 N
m
The crimp terminals conforming to the equipment connector boards are as shown in the following table.
Connector board
Crimp terminal
width
Compatible crimp terminal
Power supply
connector board
Up to 9.0 mm
O type: 1.25-4, 2-4 or Y type: 1.25-4, 2-4
Connector
Up to 2.0 mm
Flat type 1.25-AF2.3B
Keep cables connected to the unit as far away as possible from sources of noise such as power lines or
control interfaces.
The conduit should house exclusively cables connected to the equipment itself. Avoid joint use with
other lines in the conduit.
Always ground the equipment. Use Type D single grounding. Do not share a ground with the power
supply system.
Use shielded cable for the external control input/output connections, and connect the shield wire to
the F.G. Terminal on the power supply connector board.
Torque Transducer Connection
This equipment can be connected to an optical transmission flange-type torque transducer.
Torque transducers that can be connected to the equipment
Torque
transducer
Cable
Frequency output
range
OPT-564 setting
(F-54)
Notes
TMHS
CAC-176B-**M
10 kHz ±5 kHz
F-54 = 0
TMHSA
CAC-176C-**M
CAC-176B-**M
10 kHz ±5 kHz
F-54 = 0
TMHSB
CAC-176D-**M
CAC-176G-**M
240 kHz ±120 kHz F-54 = 1
TMOFB
CAC-169B-**M
10 kHz ±5 kHz
F-54 = 0
DBX-001 is required.
TMHFB
CAC-169B-**M
10 kHz ±5 kHz
F-54 = 0
DBX-001 is required.
TMOS
CAC-169B-**M
10 kHz ±5 kHz
F-54 = 0
DBX-001 is required.
The frequency output will vary depending on the torque transducer. Alter the OPT-564 setting to suit
the torque transducer used. (Set using F-54.)
The DBX-001 power supply box is also required if using the TMOFB/TMHFB/TMOS torque
transducers with this equipment.
Содержание OPT-564
Страница 1: ...DIGITAL TRANSMITTER OPT 564 Instruction Manual EN294 1924B ...
Страница 2: ......
Страница 12: ......
Страница 80: ...68 Frequency Output Shield Frequency counter or other device ...
Страница 114: ...102 External View The individual component dimensions are as follows Front Rear Units mm Panel cut out dimensions Side ...