Output connection
Terminal
No.
Signal
Operation
5
COM
The common for input/output terminals (terminals 1 to 4 and 6
to 9).
7
ERROR OUT
Turns on when an error occurs.
* Errors refer to the errors described in Section 12-2 Error Display and light level status errors.
The external control output common (terminal No. 5) is insulated from the other common (terminal
No. 17).
To protect external control output, add a suitable surge protector for the load.
Load
Surge protector
V
CE
7
COM
5
Open collector rating
V
CE
: 35 V DC
I
C
: 40 mA DC