39
Monitor Mode
Monitor mode displays the current torque value output from the torque transducer as a frequency.
Monitor mode can be selected from measurement mode as follows.
appears in the upper part when the
key is
depressed for approximately 2 seconds in measurement mode.
The upper display reads
when the
key is
pressed nine times.
The upper display reads
and the lower display
shows a numerical value when the
key is pressed.
The numerical value displayed indicates the current torque value
output from the torque transducer as a frequency.
For further details, see the torque transducer test results.
The upper display reads
when the
key is
pressed.
Press the
key to exit monitor mode and return to
measurement mode.
Current torque value
When F-54 is set to 0, the
units are Hz.
Example: 10000 is 10 kHz
When F-54 is set to 1, the
units are 10 Hz.
Example: 24000 is 240 kHz