Span calibration error display
When F-54 is 0 (10 kHz ±5 kHz specifications)
The display flashes for approximately 2 seconds when ([span point torque
transducer output frequency or span point torque transducer value entered] -
[zero point torque transducer output frequency or zero point torque transducer
value entered]) ≤ 0 or when the torque transducer output frequency is less than
14,500 Hz or if the value entered is less than 14,500 Hz.
The display flashes for approximately 2 seconds when the torque transducer
output frequency exceeds 15,500 Hz or if the value entered exceeds 15,500 Hz.
When F-54 is 1 (240 kHz ±120 kHz specifications)
The display flashes for approximately 2 seconds when ([span point torque
transducer output frequency or span point torque transducer value entered] -
[zero point torque transducer output frequency or zero point torque transducer
value entered]) ≤ 0 or when the torque transducer output frequency is less than
348,000 Hz or if the value entered is less than 348,000 Hz.
The display flashes for approximately 2 seconds when the torque transducer
output frequency exceeds 372,000 Hz or if the value entered exceeds
372,000 Hz.
In span calibration, use a torque value of at least 2/3 of the display torque to minimize calibration
errors.
Ending Calibration
Displays
after calibration ends.
Press the
key to exit calibration mode.
The system switches to measurement mode and the data set is registered.
The calibration values (zero and span calibration) will not be entered unless the procedure is
performed in sequence up to this step.
Calibration can be performed only in the counter-clockwise torsional direction. Refer to Section 4-3.
The A/Z function is canceled once calibration is completed.
Measurement
Mode