47
Function No.
Item
Setting
value
Details
F-10
Torque stabilization filter
Time width setting
000 to 999 Unit: 10 ms
000: Torque stabilization filter off
000
F-11
Torque stabilization filter
Data width setting
00 to 99
Unit: DIGIT
00: Torque stabilization filter off
20
F-15
Rotation speed stabilization
filter
Number of moving-average
samples
0
No. of moving-average samples: 1
1
No. of moving-average samples: 2
2
No. of moving-average samples: 4
3
No. of moving-average samples: 8
4
No. of moving-average samples: 10
5
No. of moving-average samples: 12
6
No. of moving-average samples: 14
7
No. of moving-average samples: 16
8
No. of moving-average samples: 32
F-16
Rotation speed stabilization
filter
Time width setting
000 to 999 Unit: 10 ms
000: Rotation speed stabilization filter off
000
F-17
Rotation speed stabilization
filter
Data width setting
00 to 99
Unit: DIGIT
00: Rotation speed stabilization filter off
20
F-18
Key lock
00000
to 11111
00000
0: Off
1: On
10
0
digit:
10
1
digit:
10
2
digit:
10
3
digit:
10
4
digit:
F-19
Polarity change
0
Torque in counter-clockwise direction is
positive.
1
Torque in clockwise direction is positive.
F-20
CHECK value
0 to 20
Refer to Section 9-2-3.
16
F-21
Torque analog output
Max. display value
1 to 99 999
Unit: DIGIT
10 000
F-22
Rotation speed analog output
Max. display value
1 to 27 500
Unit: DIGIT
25 000