© 2014 MIMAKI ENGINEERING CO.,LTD.
4.2.15
P.1
1
2
3
4
5
6
7
8
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > POINTER OFFSET
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver.
1.00
Remark
1.0
Rev.
R.1.0
4.2.15 POINTER OFFSET
Function
Print the adjustment pattern and adjust the location of the LED pointer and print origin (Nozzle A Column).
Procedure
1. Select [#ADJUST] - [POINTER OFFSET].
2. Make necessary adjustments.
[ENTER]: Starts drawing.
After drawing is completed
[
], [
], [
], [
] : LED pointer movement
Align the LED pointer to the pattern position
shown on the left (intersection of the straight
lines).
[ENTER]: Settings
[END]: Cancellation of input
FUNCTION
#ADJUST
[ENT]
#ADJUST
POINTER OFFSET [ENT]
LED Pointer
This function perform adjusting only once.
When drawing is performed, readjustment is
necessary because adjustment value is reset.