5.1.15 HEATER
Function
Temperature tests of the media heater, ON/OFF test of heater are executed.
Operation Procedures of “TEMP.”
Purpose: Check that heater temperature control can operate normally.
Contents: The operation is same when the HEATER key is pressed in LOCAL. However, the changed value is not
saved.
Operation Procedures of “SSR”
Purpose: Check the heater operation and the A/D value.
Contents: The ON heater temperature moves up. If it is left, it may exceed the upper limit of the setting value. Be
careful about it.
Temperature is displayed with a unit selected in the [UNIT SETUP] of the [MACHINE SETUP] function.
A/D conversion value is also displayed.
Step
Item
Description
Remarks
1
Temperature setting
Sets temperature of Pre, Print, and Post Heater to control the heater.
Set value (Celsius): OFF, 20 – 70
C (unit: 1
C)
Set value (Fahrenheit): OFF, 68 – 122
F (Because conversion is used, the unit is
not 1
F)
2
Temperature display
[END]: Returns to temperature setting.
Step
Item
Description
Remarks
1
ON/OFF setting
Designates ON/OFF of Pre, Print and Post Heater.
The temperature of the heater you turned on will rise. Be aware that if
left alone, it may exceed the set upper limit.
Temperature is not controlled.
2
ON/OFF display
[END]: Returns to setting screen.