7.1.4 List of SYSTEM HALT
1
2
3
4
5
6
7
8
13
SYSTEM HALT (*)
115 : PCB MAIN-F1
MAIN PCB fuse (F1) disconnected (+IO5V)
Replace the MAIN PCB with a new one.
(
See 3.3.1)
Confirm the below before replacement.
1.
2.
14
SYSTEM HALT (*)
12d : PCB MAIN-F4
MAIN PCB fuse (F4) disconnected (+IOPOW)
15
SYSTEM HALT (*)
1bf : PCB MAIN-F2/F3
MAIN PCB fuse (F2 or F3) disconnected (+SLD
POW1 FFC or Cable)
Replace the MAIN PCB with a new one.
(
See 3.3.1)
Confirm the below before replacement.
1.
2.
16
SYSTEM HALT (*)
1c0 : PCB MAIN-F5/F6
MAIN PCB fuse (F5 or F6) disconnected (+SLD
POW2 FFC or Cable)
17
SYSTEM HALT (*)
1af : PCB COMIO-F1
COM32 IO PCB fuse (F1) disconnected
(+42VCAS)
Replace the COM32 IO PCB with a new one.
Confirm the below before replacement.
1.
2.
18
SYSTEM HALT (*)
1b0 : PCB COMIO-F2
COM32 IO PCB fuse (F2) disconnected (+42V-
s-FUSE)
19
SYSTEM HALT (*)
1b1 : PCB COMIO-F3
COM32 IO PCB fuse (F3) disconnected (+IO5V-
FUSE)
20
SYSTEM HALT (*)
1b2 : PCB COMIO-F4
COM32 IO PCB fuse (F4) disconnected (+24V-
FUSE)
21
SYSTEM HALT (*)
1b3 : PCB SLDR2H-F1
SL2H PCB fuse (F1) disconnected (+3.3V-
FUSE)
Replace the SL2H PCB with a new one.
Confirm the below before replacement.
1.
2.
22
SYSTEM HALT (*)
1b4 : PCB SLDR2H-F2
SL2H PCB fuse (F2) disconnected (+4.2V-
FUSE)
23
SYSTEM HALT (*)
1b5 : MAIN CN6
1. Check the connections between the SL2H PCB and the
MAIN PCB, and then disconnect and connect the FFC.
2. Replace the above FFC.
3. Replace the SL2H PCB with a new one.
4. Replace the MAIN PCB with a new one.
(
See 3.3.1)
24
SYSTEM HALT (*)
1b6 : COMIO CN26
1. Remove the FFC connected to CN26 on the COM32
IO PCB.
25
SYSTEM HALT (*)
1b7 : COMIO CN27
1. Check the connections between the COM32 IO PCB
and the Sl2H PCB, and then disconnect and connect
the FFC.
2. Replace the above FFC.
3. Replace the COM32 IO PCB with a new one.
4. Replace the Sl2H PCB with a new one.
26
SYSTEM HALT (*)
1b8 : COMIO CN28
27
SYSTEM HALT (*)
1b9 : COMIO CN30
28
SYSTEM HALT (*)
1ba : COMIO CN31
29
SYSTEM HALT (*)
1bb : COMIO VHV1 OC
1. Replace the COM32 IO PCB with new one.
30
SYSTEM HALT (*)
1bc : COMIO VHV2 OC
31
SYSTEM HALT (*)
1bd : COMIO VHV3 OC
32
SYSTEM HALT (*)
1be : COMIO VHV4 OC
33
SYSTEM HALT (*)
1c1 : PCB COMIO
No COM32 IO PCB
An error occurred at serial communication check
after configuration.
1. Check the connections between the COM32 IO PCB
and the MAIN PCB, and then disconnect and connect
the FFC.
2. Replace the above FFC.
3. Replace the COM32 IO PCB with a new one.
4. Replace the MAIN PCB with a new one.
(
See 3.3.1)
34
SYSTEM HALT (*)
1c3 : PCB SLDR2H
No SL2H PCB
An error occurred at serial communication check
after configuration.
1. Check the connections between the SL2H PCB and the
MAIN PCB, and then disconnect and connect the FFC.
2. Replace the above FFC.
3. Replace the SL2H PCB with a new one.
4. Replace the MAIN PCB with a new one.
(
See 3.3.1)
List of SYSTEM HALT (2/5)
No.
LCD
Cause
Corrective Measures