© 2014 MIMAKI ENGINEERING CO.,LTD.
6.3.5
P.1
1
2
3
4
5
6
7
8
6.3.5 Linear Encoder Scale
Work procedures
1. Remove the following covers.
• Front cover M, L
• Carriage cover
• Front under cover
2. Remove the
Encoder PCB Assy
.
•
"6.4.8 Encoder PCB Assy"
3. Loosen the screws from the Y-SP plate on the left side of the
main body, and release the tension of the Y drive belt.
4. Remove the screws from the right end of the linear encoder
scale, and detach the
Scale holder R
and
Linear encoder scale
.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
While at work, be sure not to attach fingerprints or oil to the linear encoder scale. Also, pay attention not
to break or scratch it. (If contaminated, clean the scale with a neutral detergent.)
Linear Encoder Scale
Y-SP plate
Loosen
Workable from the
cover outside
You can access a screw from hole of the cover L.
Linear encoder scale
Scale holder R
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > Linear Encoder Scale
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.