© 2014 MIMAKI ENGINEERING CO.,LTD.
3.1.7
P.1
1
2
3
4
5
6
7
8
R.1.0
MAINTENANCE MANUAL > Workflow > Ink Related Parts > Replacement of the Cap Head Assy.
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver.
1.00
Remark
1.0
Rev.
3.1.7 Replacement of the Cap Head Assy.
List of replacement procedures
Item
Work operation
Description
Ref.
Covers
1.
Removal of covers, etc.
Remove the Front cover M, L and under cover R.
6.1.1
Cap Assy
2.
Removal of the Cap Assy.
Remove the Cap Assy.
6.2.6
3.
Mounting of the Cap Assy.
Attach the Cap Assy while pushing it toward you.
6.2.6
4.
Adjustment of Capping
Carry out “CAPPING” (by using the key) [# ADJUST].
CAPPING POS: the cap slider is located at 3 mm to the
right from the uppermost point it has
reached on the cap base3 mm to the right
from the uppermost position of the cap
slider.
AirPullPOS.:
the clearance between the head and
uppermost point of the cap is set at 0.5
mm.
FlushingPOS:
the clearance between the head and
uppermost point of the cap is set at 1
mm.
4.2.6
Check
5.
Cleaning operation
Check whether each assembly and adjustment has been
carried out properly.
Covers
6.
Mounting of the covers.
Mount the covers that have been removed.
6.1.1
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Cap head Assy.