© 2014 MIMAKI ENGINEERING CO.,LTD.
6.4.4
P.1
1
2
3
4
5
6
7
8
6.4.4 AC PCB Assy
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the
Platen cover F
.
3. Remove the
Heater PCB cover
(screw x2).
4. Disconnect all
connectors
on PCB.
5. Remove the screws (x4) and then remove the
AC PCB Assy
.
6. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15 minutes
before restarting the operation. It is very dangerous if sleep mode functions mistakenly during the
operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pressure
part of PCBs. Take care to avoid contact with it.
AC PCB Assy
Heater PCB cover
AC PCB Assy
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > AC PCB Assy
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.