© 2014 MIMAKI ENGINEERING CO.,LTD.
7.1.4
P.3
7.1.4 List of SYSTEM HALT
1
2
3
4
5
6
7
8
35
SYSTEM HALT (*)
303 : PCB MAIN ET
MAIN PCB Ethernet IC trouble
1. Replace the MAIN PCB with a new one.
(
See 3.3.1)
36
SYSTEM HALT (*)
406 : WIPER ORG
Wiper origin undetectable
1. Execute and confirm [#TEST][SENSOR]
[WIPER-ORG]. (Confirm that the ON/OFF display is
switched by moving the wiper back and forth.)
2. Check that the wiper moves back and forth smoothly in
manual.
3. Check the assembly and connector connection of Wiper
Origin Sensor.
4. Check the connector connection of Y-origin Sensor
5. Check the connections between the COM32 IO PCB
and the MAIN PCB, and then disconnect and connect
the FFC.
6. Replace the Wiper Back/Forth Origin Sensor with a
new one.
7. Replace the Wiper Motor with a new one.
8. Replace the FFC located between the Central-IO PCB
and the MAIN PCB.
9. Replace the Central-IO PCB with a new one.
(
See 6.4.9)
37
SYSTEM HALT (*)
42c : TAKEUNIT VOLT
An error occurred in the take-up unit
voltage.
1. Check the connection of the heavy weight media
winding unit.
2. If the abnormality occurs again after checking the
connection, replace the circuit board of the heavy
weight media winding unit.
38
SYSTEM HALT (*)
42d : FEEDUNIT VOLT
An error occurred in the feeding unit
voltage.
1. Check the connection of the heavy weight media
feeding unit.
2. If the abnormality occurs again after checking the
connection, replace the circuit board of the heavy
weight media feeding unit.
39
SYSTEM HALT (*)
430 : TAKEUNIT SENS
An error occurred in the take-up unit sensor. 1. Check the status of the sensor of the heavy weight
media winding unit and the fixing position of the
sensor.
2. If the error occurs again after checking, replace the
heavy weight media winding board.
40
SYSTEM HALT (*)
431 : FEEDUNIT SENS
An error occurred in the feeding unit sensor. 1. Check the status of the sensor of the heavy weight
media feeding unit and position of sensor fixing.
2. If the error occurs again after checking, replace the
heavy weight media winding board.
41
SYSTEM HALT (*)
502 : Y ORGIN
Y Origin Sensor error
1. Execute and confirm [#TEST][SENSOR] ->
[Y-ORIGIN]. (Confirm that the ON/OFF display is
switched by moving the carriage left and right.)
2. Check in manual if the carriage moves left and right
smoothly.
3. Check the connector connection of Y-origin Sensor
and then disconnect and connect the cabel.
4. Replace the Y Origin Sensor with a new one.
5. Check if there is no trouble on theY Motor Cable.
(disconnecting, burnout, or the like)
6. Replace the Y-axis motor with a new one.
(
See 6.3.2)
7. Replace the HDC PCB with a new one.
8. Replace the MAIN PCB with a new one.
(
See 3.3.1)
List of SYSTEM HALT (3/5)
No.
LCD
Cause
Corrective Measures
R.1.0
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.10
Remark
1.0
Rev.