6.5.4 Detector Assy, I/C, Y
Work procedures
1. Remove the
Cartridges
.
2. Remove the
Cartridge cover
and
Cartridge rear cover
.
3. Remove the
CART IO PCB Assy
(screw x4).
(Refer to
6.4.6
.)
4. Remove the
Fitting
.
5. Remove the
Cartridge base
(screw x4).
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Detector Assy., I/C, Y x8
Remove fitting
Make sure that O-ring (F seal rubber 300) is not
remaining in the joint screws.
F seal rubber 300
Cartridge base
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Detector Assy, I/C, Y