© 2014 MIMAKI ENGINEERING CO.,LTD.
6.2.8
P.1
1
2
3
4
5
6
7
8
6.2.8 Cap Head Assy
Work procedures
1. Turn off the main power supply of the machine.
2. Manually move the head unit over the platen.
3. Remove the
Cap slider cover
and the
CP absorber
by pushing
the stopper.
4. While pushing down the
Cap head Assy
, slide it to the left or
right, and remove it.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Cap Head Assy
Cap slider cover
Push stopper
Cap head Assy.
Slide horizontal
while pushing
down
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Cap Head Assy
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.